AWS-SGA |
This high quality Strain Gage Amplifier provides the "analog front end" - the basic interface module - for connecting a strain gage load cell/scale to a customer's analog or digital control systems. The superior stability, adjustable gain and 3-pole active filter make this module ideal for automated industrial weighing systems.
| Power Requirement | 115 VAC, 50/60 Hz, 10VA |
| Optional | 30 VAC (Specify When Ordering) |
| Signal Input Range | ± 2 to 22 MV dc |
| Voltage Output | ± 2 volts DC Standard; ± 5 volts DC Optional |
| Gain Adjustment | 50 - 1000 |
| Zero Offset | ± Full Scale |
| Filter | 3-Pole Active; 10 Hz |
| Load Cell Excitation | 16 Volts DC at 200 MA Max. |
| Temperature Coeffecient | ± 0.002 /degree F |
| Dimensions | 5.31" X 8.5 " X 1.75" |
![]() ![]() |
W3C® is registered in numerous countries of the World Wide Web Consortium. No endorsement or relationship is implied. Advance Weight Systems, Inc. displays this to show that extreme care is taken even in the design of our web sites. Validate any web page for valid code. |
This page was last modified:
|